<?xml version="1.0" encoding="utf-8" standalone="no"?>
<!DOCTYPE article SYSTEM "http://www.atmos-chem-phys.net/inc/acp/copernicus.dtd">
<article language="en">
	<journal>
		<journal_title>Atmospheric Chemistry and Physics</journal_title>
		<journal_url>www.atmos-chem-phys.net</journal_url>
		<issn>1680-7316</issn>
		<eissn>1680-7324</eissn>
		<volume_number>8</volume_number>
		<issue_number>16</issue_number>
		<publication_year>2008</publication_year>
	</journal>
	<doi>10.5194/acp-8-4865-2008</doi>
	<article_url>http://www.atmos-chem-phys.net/8/4865/2008/</article_url>
	<abstract_html>http://www.atmos-chem-phys.net/8/4865/2008/acp-8-4865-2008.html</abstract_html>
	<fulltext_pdf>http://www.atmos-chem-phys.net/8/4865/2008/acp-8-4865-2008.pdf</fulltext_pdf>
	<start_page>4865</start_page>
	<end_page>4875</end_page>
	<publication_date>2008-08-21</publication_date>
	<article_title content_type="html">Intercomparison of erythemal broadband radiometers calibrated by seven UV calibration facilities in Europe and the USA</article_title>
	<authors>
		<author numeration="1" affiliations="1">
			<name>G. Hülsen</name>
			<email>gregor.huelsen@pmodwrc.ch</email>
		</author>
		<author numeration="2" affiliations="1">
			<name>J. Gröbner</name>
		</author>
		<author numeration="3" affiliations="2">
			<name>A. Bais</name>
		</author>
		<author numeration="4" affiliations="3">
			<name>M. Blumthaler</name>
		</author>
		<author numeration="5" affiliations="4">
			<name>P. Disterhoft</name>
		</author>
		<author numeration="6" affiliations="5">
			<name>B. Johnsen</name>
		</author>
		<author numeration="7" affiliations="4">
			<name>K. O. Lantz</name>
		</author>
		<author numeration="8" affiliations="2">
			<name>C. Meleti</name>
		</author>
		<author numeration="9" affiliations="6">
			<name>J. Schreder</name>
		</author>
		<author numeration="10" affiliations="7">
			<name>J. M. Vilaplana Guerrero</name>
		</author>
		<author numeration="11" affiliations="8">
			<name>L. Ylianttila</name>
		</author>
	</authors>
	<affiliations>
		<affiliation numeration="1" content_type="html">Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center, Dorfstrasse 30, 7278 Davos Dorf, Switzerland</affiliation>
		<affiliation numeration="2" content_type="html">Aristotle University of Thessaloniki, Laboratory of Atmospheric Physics, Campus Box 149, 541 24 Thessaloniki, Greece</affiliation>
		<affiliation numeration="3" content_type="html">Innsbruck Medical University, Division for Biomedical Physics, Müllerstr. 44, 6020 Innsbruck, Austria</affiliation>
		<affiliation numeration="4" content_type="html">National Oceanic and Atmospheric Administration, Central UV Calibration Facility, 325 Broadway, 80305 Boulder, CO, USA</affiliation>
		<affiliation numeration="5" content_type="html">Norwegian Radiation Protection Authority, Grini Naeringspark 13, 1361 Osteras, Norway</affiliation>
		<affiliation numeration="6" content_type="html">CMS Ing. Dr. Schreder GmbH, Eggerstrasse 8, 6322 Kirchbichl, Austria</affiliation>
		<affiliation numeration="7" content_type="html">Instituto Nacional de Técnica Aerospacial, Estación de Sondeos Atmosféricos El Arenosillo, 21130 Mazagon, Spain</affiliation>
		<affiliation numeration="8" content_type="html">STUK, Radiation and Nuclear Safety Authority, Non-Ionizing Radiation Laboratory, P.O. Box 14, 00881 Helsinki, Finland</affiliation>
	</affiliations>
	<abstract content_type="html">A bi-lateral intercomparison of erythemal broadband radiometers was performed
between seven UV calibration facilities. The calibrations provided by the
instruments owners were compared relative to the characterisation and
calibration performed at PMOD/WRC in Davos, Switzerland. The calibration
consisted in the determination of the spectral and angular response of the
radiometer, followed by an absolute calibration performed outdoors relative
to a spectroradiometer which provided the absolute reference.

&lt;br&gt;&lt;br&gt;

The characterization of the detectors in the respective laboratories are in
good agreement: The determinations of the angular responses have deviations
below &amp;plusmn;4% and the spectral responses agree within &amp;plusmn;20%. A &quot;blind&quot;
intercomparison of the erythemally weighted irradiances derived by the
respective institutes and PMOD/WRC showed consistent measurements to within
&amp;plusmn;2% for the majority of institutes. One institute showed slightly
larger deviation of 10%. The differences found between the different
instrument calibrations are all within the combined uncertainty of the
calibration.</abstract>
	<references>
		<reference numeration="1" content_type="text"> Bais, A., Kazadzis, S., Balis, D., Zerefos, C., and Blumthaler, M.: Correcting global solar ultraviolet spectra recorded by a Brewer spectroradiometer for its angular response error, Appl. Optics, 37, 6339–6344, 1998. </reference>
		<reference numeration="2" content_type="text"> Gröbner, J. and Sperfeld, P.: Direct traceability of the portable QASUME irradiance scale to the primary irradiance standard of the PTB, Metrologia, 42, 134–139, 2005. </reference>
		<reference numeration="3" content_type="text"> Gröbner, J., Blumthaler, M., and Ambach, W.: Experimental investigation of spectral glabal irradiance measurement errors due to a non ideal cosine response, Geophys. Res. Lett., 23, 2493–2496, 1996. </reference>
		<reference numeration="4" content_type="text"> Gröbner, J., Kazadzis, S., Schreder, J., Bais, A F., Blumthaler, M., Görts, P., Koskela, T., Seckmeyer, G., Webb, A R., and Wuttkeand, S.: Quality assurance of spectral ultraviolet measurements in Europe through the development of a transportable unit, Doc. EUR 20991 EN (European Commission, 2003), 2003. </reference>
		<reference numeration="5" content_type="text"> Gröbner, J., Schreder, J., Kazadzis, S., Bais, A F., Blumthaler, M., Görts, P., Tax, R., Koskela, T., Seckmeyer, G., Webb, A R., and Rembges, D.: Traveling reference spectroradiometer for routine quality assurance of spectral solar ultraviolet irradiance measurements, Appl. Optics, 44, 5321–5331, 2005. </reference>
		<reference numeration="6" content_type="text"> Gröbner, J., Blumthaler, M., Kazadzis, S., Bais, A., Webb, A., Schreder, J., Seckmeyer, G., and Rembges, D.: Quality assurance of spectral solar UV measurements: results from 25 UV monitoring sites in Europe, 2002 to 2004, Metrologia, 43, 66–71, 2006. </reference>
		<reference numeration="7" content_type="text"> Gröbner, J., Hülsen, G., Vuilleumier, G L., Blumthaler, M., Vilaplana, J M., Walker, D., and Gil, J E.: Report of the PMOD/WRC-COST Calibration and Intercomparison of Erythemal Radiometers, prefixhttp://i115srv.vu-wien.ac.at/uv/COST726/COST726_Dateien/Resul% ts/PMOD_WRC_COST726_campaign_2006_R.pdf, 2007. </reference>
		<reference numeration="8" content_type="text"> Hülsen, G. and Gröbner, J.: Characterization and calibration of ultraviolet broadband radiometers measuring erythemally weighted irradiance, Appl. Optics, 46, 5877–5886, 2007.   </reference>
		<reference numeration="9" content_type="text"> ISO: Erythema reference action spectrum and standard erythema dose, International Organization for Standardization, ISO/CIE 17166:1999, 1999. </reference>
		<reference numeration="10" content_type="text"> Lantz, K., Disterhoft, P., DeLuisi, J., Early, E., Thompson, A., Slusser, J., and Bigelow, D.: A Methodology for Deriving Clear-Sky Erythema Calibration Factors for UVB Broadband Radiometers of the CUCF, J. Atmos. Ocean. Tech., 16, 1736–1752, 1999. </reference>
		<reference numeration="11" content_type="text"> Leszczynski, K., Jokela, K., Ylianttila, L., Visuri, R., and Blumthaler, M.: Erythemally weighted radiometers in solar UV monitoring: Results from the WMO/STUK Intercomparison, Photochem. Photobiol., 67, 212–221, 1998. </reference>
		<reference numeration="12" content_type="text"> Mayer, B. and Kylling, A.: The libRadtran software package for radiative transfer calculations – description and examples of use, Atmos. Chem. Phys., 5, 1855–1877, 2005. </reference>
		<reference numeration="13" content_type="text"> McKinlay, A. and Diffey, B.: A reference action spectrum for ultraviolet induced erythema in human skin, CIE Journal, 6, 17–22, 1987. </reference>
		<reference numeration="14" content_type="text"> Müller, G., Artz, R., Baltensperger, U., Carmichael, G., Dlugokencky, E., Penkett, S., Stähelin, J., Webb, A., Hov, O., Klausen, J., Sturges, B., Barrie, L., Braathen, G., Jalkanen, L., and Nickovic, S.: WMO Global Atmosphere Watch (GAW) Strategic Plan: 2008–2015, World Meteorological Organization WMO/GAW Rep., WMO TD NO. 1384, prefixhttp://www.wmo.int/pages/prog/arep/gaw/documents/gaw172_sp_15% may.pdf, 2007. </reference>
		<reference numeration="15" content_type="text"> Schreder, J., Gröbner, J., Los, A., and Blumthaler, M.: Intercomparison of monochromatic source facilities for the determination of the relative spectral response of emal broadband filter radiometers, Opt. Lett., 29, 1455–1457, 2004. </reference>
		<reference numeration="16" content_type="text"> Webb, A., Gröbner, J., and Blumthaler, M.: A Practical Guide to Operating Broadband Instruments Measuring Erythemally Weighted Irradiance, prefixhttp://i115srv.vu-wien.ac.at/uv/COST726/COST726_Dateien/Resul% ts/GuideBB_COST726.pdf, EUR 22595, ISBN 92-898-0032-1, 2006. </reference>
	</references>
</article>

